Need Help? (720) 278-4104 8am - 6pm MST.

Selling pre-owned medical equipment

Shop Now!

SIEMENS Advia 1200 Chemistry Analyzer

Product Overview

The Flexibility of Innovation
Compact Size: The ADVIA® 1200 system features a small footprint, which allows it to fit comfortably in any size laboratory.

Productivity – Reliability – Expertise

  • Sample Tray:
    Capacity for 84 patient samples. Separate access to refrigerated area for on-board calibrators and controls.
  • Sample Probe:
    Sampling system includes liquid level sensing, short sample detection and clot detection. The ADVIA 1200 system has minimal requirements for sample volume (as low as 1 µL/test).
  • ISE System:
    Indirect Na+, K+, Cl-.Compact, easy to replace, long-life electrodes guaranteed for 30,000 tests per electrode.
  • Cuvette-based Reaction Tray:
    Segmented tray for easy cuvette replacement. This advanced, high precision optical system combines with a unique incubation fluid and a concavity diffraction grating to ensure superior precision and accuracy in clinical chemistry instrumentation.
  • Reagent Storage Area:
    Refrigerated storage for 41 one- or two-reagent chemistries plus open system capability – providing total workstation consolidation.

Product Features:

  • Open system: Open
  • Throughput: 800 samples/hour, 1200 w/ise
  • Parameters: 44 assays
  • Method: Spectrophotometric

Dimensions: 48(W) x 33(D) x 43(H) inches

SIEMENS Advia 1200 Chemistry Analyzer

ROCHE Cobas Mira S Chemistry Analyzer

Product Features:

  • Optional ISE module for sodium, potassium and chloride determinations
  • 104 test channels including 26 for profiles and 26 for ratio calculation
  • Holds 4000 patient results
  • Recertified with 90 day parts warranty
  • Reagents, controls, and consumables may be available
  • Direct sampling capability
  • Microprocessor controlled XYZ pipetting system

ROCHE Cobas Mira S Chemistry Analyzer

ROCHE Cobas Mira Plus Chemistry Analyzer

Product Overview:

Roche Cobas Mira Plus is a fully programmable analyzer providing trouble-free operation, random-access testing and a broad test menu. Its integrated control panel allows operator select tests, evaluate results and program tests, profiles and system parameters. In addition, it has many automated features that include automated post-dilution, on-board reagent cooling and automated electrode calibration.

The system is a bench top analyzer with 104 programmable test channels. Its optional ISE module with new electrodes allows the automatic calibration of sodium, potassium and chloride levels. It has 72 cuvettes capacity and an analysis interval of 25 seconds. With Laboratory Information System (LIS) options, it provides results in the format that you request.

Product Features:

  • STAT testing capability
  • End point assay method
  • Variable rack system for calibrators, reagents, samples and quality control material
  • Closed primary tube sampling
  • Direct sampling capability
  • Photometric colorimetric optical system

ROCHE Cobas Mira Plus Chemistry Analyzer

ROCHE Cobas Integra 800 Chemistry Analyzer

Product Overview:

The ROCHE Cobas Integra 800 Chemistry Analyzer is designed to support you in achieving improved cost efficiency in an environment where the pressure to cut costs is constantly increasing. The ROCHE Cobas Integra 800 Chemistry Analyzer is an intelligent tool for more productive organization and processing of the daily laboratory workload, helping you to optimise use of available resources and eliminate unnecessary manual interactions. The Integra 800 also ensures security of the result quality. The reagents concept and quality combined with automatic system control mechanisms, like Pipetting Integrity Check, reduce reruns and manual handling of samples and reagents. The ROCHE Cobas Integra 800 Chemistry Analyzer is the right solution for workload consolidation and workflow optimization, especially for special chemistry and HBA1c testing in the high volumes sites.

Product Specifications:

System:

  • Random and continuous access, sample selective analyzer
  • Integration of 4 measuring principles
  • 72 tests onboard
  • Absorbance Photometry: Enzymes and Substrates
  • Turbidimetry: Specific Proteins, Drugs of Abuse
  • Fluorescence Polarimetry: Therapeutic Drugs, Thyroid Tests
  • Ion-Selective Electrode
  • Potentiometry: Na+, K+, Cl– and Li+

Test Throughput:

Up to 855 tests/hr (including electrolytes)

Sample Types:

Serum, Plasma, Urine, CSF, Hemolysate and Whole Blood

Sample Handling:

Rack system for samples, calibrators and controls:
RD5 rack, RD15 rack, RD12+3 rack, Multi Rack; Roche standard rack and tray compatibility; In- and Out-Tray for 75 samples each;
Automatic predilution; User definable postaction 1 & 2: dilute or concentrate; Temperature controlled: calibrators and controls, 20°C (68°F) Samples below 32°C (90°F); Barcode reading via LED scanner, with immediate STAT recognition

Sample Container Types:

Primary tubes: 5 to 10ml; 16×100, 16×75, 13×100, 13x75mm with closed cap for systems with closed tube sampling option for HbA1c.
(please contact Roche for list of compatible suppliers); Hitachi microcup, 500µl; Hitachi standard cup, 1.5ml; COBAS cup, 650µl; Eppendorf cup, 1.5ml; Cup on tube definable

Sample Volume:

Typically 2 to 10µl per test, ISE indirect 20µl, ISE direct 97µl

Sample Barcode Types:

Code 128, Codabar, Code 2 of 5 interleaved, Code 39

Reagents Onboard capacity:

  • 68 cobas c packs, 50-800 tests per cobas c pack
  • Reagent compartment cooled to 8°C
  • Onboard stability up to 6 months, calibration typically each lot

User Defined Reagents:

Up to 5 Development Channels are available on request.

Reaction Cells:
Holds 3000 disposable cuvettes with 5mm path length, and 120-240µl reaction volume

Control Unit:

HP workstation with RISC processor running X Windows

System Interfaces:

RS 232 serial interface, bi-directional host interface, secured digital (web based) TeleService connection to Roche for screen sharing and remote help

Electrical Requirements:

100-125/200-240 Volts AC, 50 or 60Hz, consumption 1700VA

Physical Dimensions:

Width: 190cm (74.8in); Depth: 90cm (35in); Height: 120 cm (47.3in)
Weight 512kg (1126lbs)

Water Requirements:

5-7 liters per hour in operating mode, Type 1 NCCLS

Certification:

CE, UL, C-UL

ROCHE Cobas Integra 800 Chemistry Analyzer

ROCHE Cobas Mira Plus CC Chemistry Analyzer

Product Overview:

COBAS MIRA system is an open random access analyzer with a throughput of up to 215 assays per hour. The MIRA system features simple rack handling made possible using X-Y-Z robotics. The COBAS MIRA plus system introduced in the 90’s allows pipetting from bar coded primary tubes. It became established as the best selling analyzer of its class in Clinical Chemistry. What a legacy!

The combination of these chemistry testing features has made the COBAS MIRA line of chemistry analyzers the most valued in its class. Setting new standards in chemistry performance- the COBAS MIRAS combines reliability- convenience- flexibility – and now a new level of safety for routine profiles- special chemistries- TDMs- drugs of abuse- STATs and electrolytes.

Product Specifications:

System Principle: Random Access test selective analysis

System Throughput tests/hr: Up to 132 and 204 with ISE Module

Sample Capacity: Up to 90

Reagent Capacity: Up to 43 with ISE module

Cuvette Capacity: 72 on Cobras Mira Plus

ROCHE Cobas Mira Plus CC Chemistry Analyzer

ROCHE Cobas Mira Chemistry Analyzer

Product Features:

  • Capacity for 72 cuvettes (six 12 cuvette segments)
  • 104 test channels including 23 preprogrammed methods
  • Holds 2100 patient results
  • Recertified with 90 day parts warranty
  • Reagents, controls, and consumables may be available
  • Optional ISE module (Na+, K+, Cl-)
  • Microprocessor controlled XYZ pipetting system
  • Throughput of 140 tests/hr
  • Testing sequence by patient

ROCHE Cobas Mira Chemistry Analyzer

ROCHE Cobas C 111 Chemistry Analyzer

Product Overview:
The cobas c 111 analyzer is the smallest member of Roche’s cobas platform family. It offers laboratories
receiving up to 50 samples/day a compact solution for clinical chemistry, electrolyte and homogeneous immunoassay testing. The system is designed to
fulfill the important needs of integrated laboratory networks serving outpatient and emergency laboratories, as well as private laboratories serving primary care physicians.

Product Specifications:

System:

  • Cobas c 111 analyzer
  • Discrete, fully-selective system for clinical chemistry, ISE

Test throughput:

  • 60-85 photometric tests/hr
  • 180 ISE tests/hr
  • 60-100 tests/hr photometric and ISE mixed

Sample types:

  • Serum, plasma, urine, whole blood (HbA1c)

Sample input:

  • Continuous loading of primary and secondary tubes into 8 sample positions
  • Priority STAT sampling

Time to first result:

  • 5-10 min for photometric measurements
  • 2 min for ISE measurements

Sample container types:

  • Primary tubes: 5-10mL; 16×100, 16×75, 13×100, 13×75
  • Sample cup: 2.5mL
  • Micro Cup: 1.5mL
  • Cup on tube: Cup on 16x75mm tube, False bottom tube

Sample volume

  • Min. sample volume:
  • Primary tubes 500μL
  • Sample cup 75μL
  • Micro cup 50μL

Sample barcode types:

  • Code 128, Codabar 2 of 7, Interleaved 2 of 5, Code 3 of 9

Sample dilution:

  • 1.2-100 times

Photometer:

  • 12 wavelengths, 20 W halogen lamp, monochromatic and bichromatic measurement

Measurement principles:

  • Absorbance photometry (enzymes, substrates, specific proteins)
  • Ion selective electrode, indirect measurement (dilution 1:6)

Reagents:

  • ISE: Na+,K+,Cl–
  • 2D barcoded system reagent bottles, 50-200 tests/bottle
  • Photometric: 27 onboard reagent positions for approx. 14 assays
  • Up to 8 exchangeable reagent discs available

Reaction cells:

  • Disposable micro-cuvettes

Control unit:

  • 5.7” color touch-screen LCD (1/4 VGA)

System interfaces:

  • 2 x RS 232 serial interface, bi-directional (ASTM protocol) for host and barcode scanner
  • 2 x USB 1.1/2.0 for modem and memory stick (data loading and backup)

Electrical requirements:

  • Line voltage 100-125 V and 200-240 V AC (-15%, +10%)
  • Line frequency 50 Hz (±5%) and 60 Hz (±5%)
  • Power consumption 250 VA (320 VA with ISE)
  • Installation category II (IEC 61010-1)

External printer:

  • Printer Tool Software available to enable data transmission from the cobas c 111 instrument to nearly every standard personal computer

Water requirements:

  • Up to 3 litres/day NCCLS Type II (conductivity <1μS/cm at 25°C)

Regulatory requirements:

  • GS, CE, UL, C-UL

Open system:

  • Development channel with 1, 3 or 5 channels available

ROCHE Cobas C 111 Chemistry Analyzer

ROCHE Cobas 6000 Chemistry Analyzer

Product Overview:

The ROCHE Cobas 6000 Chemistry Analyzer is the first member of the new cobas modular platform. It offers medium workload laboratories tailor-made solutions for clinical chemistry and immunochemistry testing. The cobas® 6000 analyzer series can consolidate into one integrated platform up to 95% of your routine workload of clinical chemistry and immunoassay testing. The cobas® 6000 analyzer series automates and simplifies your lab’s workload. Fully compatible with MODULAR PRE-ANALYTICS PLUS system, the cobas® 6000 analyzer series can seamlessly integrate pre-analytical automation. We’ve made operations in your lab simpler by standardizing Roche Diagnostics analyzers with common reagent carriers, applications, analytical technologies, and software interface. With the cobas® 6000 analyzer series, there is one sample tube, one patient result report, and one LIS connection. The cobas® 6000 analyzer series gives you the power to control your lab, improve financial performance, enhance efficiency, and make a difference for the doctors and patients who rely on the critical information you provide to make vital decisions about healthcare, every day.

System:

2nd Generation SWA: modular, analytical system platform, consolidated work area for Clinical Chemistry and Immunology, expandable and re-configurable on site

Types of Modules:

  • cobas c 501 module: Photometric measuring unit (incl. ISE)
  • cobas e 601 module: Electrochemiluminescence (ECL) technology measuring unit

Number of module combinations:
7 module combinations, Up to 3 modules in one core unit

  • cobas c 501 modules 1 to 2 modules
  • cobas e 601 modules 1 to 2 modules
  • cobas c 501 | cobas e 601 modules – 2 to 3 modules (only 2 unites of 1 module type for SWA combinations possbile)

Sample throughput:

Up to 120 racks/hr or 600 samples/hr

Test throughput (theoretical max):

  • 170 up to 2,170 tests/hr – overall
  • 1,000 up to 2,000 tests/hr – with cobas c 501 modules
  • 170 up to 340 tests/hr – with cobas e 601 modules
  • 1,170 up to 2,170 tests/hr – with cobas c 501 and cobas e 601 modules

Number of channels (reagent slots):

  • Up to 151 channels, in total
  • 63 channels (including ISE, automatic setting) on cobas c 501 module
  • 25 channels on cobas e 601 module

Sample material:

Serum, Plasma, Urine, CSF

Core unit analytics:

  • Rack: 5 position rack, RD standard rack
  • Rack types: Routine, STAT, Control, Calibrator, Rerun (manual), Wash
  • Tray: Tray with 15 racks/75 samples, RD standard tray
  • STAT port: STAT samples are processed with true STAT interrupt

Sample container types:

  • Primary tubes:5 to 10 mL; 16 x 100, 16 x 75, 13 x 100, 13 x 75 mm
  • Sample cup: 2.5 mL
  • Micro cup: 1.5 mL, (exception: cobas e 601 module)
  • Cups on tube: Cup on top of a 16 x 75/100 mm tube; Cup on top of one non standard tube
  • False bottom tube (FBT): One type is definable

Sample volume:

1 – 35 µL

Sample dilution:

3 – 121 times

Sample clot detection:

Available for cobas c 501 and cobas e 601 module

Minimum sample volume:

  • Primary tubes: 700 µL
  • Sample cup: 100 µL
  • Micro cup (FTB): 50 µL

Sample barcode types:

Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39

System interfaces:

  • RS 232 serial interface, bi-directional
  • Interface to cobas link data station for cobas teleservice functionalities and automatic download

Sample data base:

10.000 routine/STAT samples

Test methods:

For photometric modules: 1 point, 1 point + prozone check, 2 point, 2 point kinetic, 2 point + prozone check, 3 point, 1 point + kinetics Rate A, Rate A + serum index, Rate A with blank, Rate B

Calibrator/QC input:
Via specified racks through the input buffer or STAT port

Calibration methods:

  • Start-up, Re-calibration
  • For photometric modules: Linear, non-linear multi-points, 2 point calibration, K-factor up to 100 different calibrators pre-programmable
  • Storage of up to 180 curves
  • Preventive calibration of the stand-by cobas c and cobas e packs on cobas c 501: Two k-factor can be defined for different sample types

QC methods:

  • For e- and photometric modules: Real-time QC, individual QC, cumulative QC
  • Up to 100 controls pre-programmable
  • Preventive QC after calibration of the stand-by cassettes/rack packs
  • Auto QC: QC without operator intervention (timer triggered)

Rerun/reflex function:

  • Automatic rerun and manual rerun
  • Automatic reflex is supported by the system, reflex request to be provided by Roche Middleware Solutions

Electrical requirements:

  • Power requirements: 230 Volts AC; 110 Volts AC 2.4 kVA (for cobas c 501 | e 601)
  • Frequency: 50 Hz or 60 Hz +/- 0.5 %

Water/waste requirements:

  • Water: Bacteria free, deionised water supply: resistance of < 1,0 µS/cm
  • Water pressure: 0.5 – 3.5 kg/cm3, (49 – 343 Kpa)
  • Biohazards waste: Separate container behind the system
  • L. concentrated: Central drain port, diameter: = 50 mm / 2 inches
  • Waste drain < waste: 100 mm above the floor / 4 inches

Water consumption:

  • Max flow rate: cobas c 501 module: approx. 40 L/hr
  • Typical consumption: cobas e 601 module: approx. 30 L/hr

Operating conditions:

  • Ambient temperature: 15 to 32 °C / 59 to 90 °F
  • Ambient humidity: 30 to 85 % (RH, without condensation)
  • Heat output: 1.5 kW (5400 kJ/hr for cobas c 501, 4320 kJ/hr for cobas e 601)
  • Noise output: < 65 dB

ROCHE Cobas 6000 Chemistry Analyzer

ROCHE Cobas E 411 Chemistry Analyzer

Product Specifications

System:
Fully automated, immunoassay analyzer for random access processing of ECL-based immunoassays (cobas e system format)

Types of modules:

  • cobas e 411 disk analyzer
  • cobas e 411 rack analyzer
  • Optional System Table (cabinet); Optional System Table Extension (for printer)

System components:

Self contained bench top analyzer comprising an analytical unit and a customized user interface

System interfaces:

RS232 serial interface, bidirectional

Throughput:

Up to 86 tests/hour

Number of reagent channels:

18 channels (reagent slots) for maximum of 18 tests

Programmable test parameters:

N/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database

Sample materials:

Serum/plasma, urine, others

Sample input/output:

  • 30 positions for samples, calibrators and controls
  • 15 racks with 5 samples each (= 75 samples in/out)

Sample volume:

10 – 50 μl

Sample clot detection:

Standard (pressure sensor)

Sample barcode types:

Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39

Control unit:

Microsoft® Windows® XP-based panel PC

Calibrator/QC input:

cobas e system-specific barcoded CalSet vials on disk or racks

Calibration methods:

Lot calibration (L-cal); Reagent Pack (RP) calibration (R-Cal)

QC methods:

  • Individual QC and cumulative QC
  • Up to 100 controls pre-programmable

Data storage capacity:
The memory contains data files necessary for the analyzer and software to work together:

  • Reagent Data File:Up to 300 reagent packs
  • Sample Data File: Up to 2000 test records (for samples and controls)
  • Calibration Data File: Up to 160 calibrators – QC Data File: Capacity up to 100 controls
  • Operating Parameter Data File: Up to 305 reagent applications
  • Up to 20 operator IDs

Electrical requirements:

  • 230/110 Volts AC; 1,000 kVA (disk), 1,250 kVA (rack)
  • Frequency: 50 Hz or 60 Hz +/- 0.5%

Water/Waste requirements:

  • Water: Bacteria free, de-ionized water supply, resistance of < 10 μS/cm
  • Liquid waste: Onboard waste container (4 liter), direct drain optional

Operating conditions:

  • Ambient temperature: 18 to 32°C
  • Ambient humidity: 20 to 80% RH (without condensation)
  • Heat Output: 2,879 kJ/hr (analyzer unit)
  • Noise Output: 60 dBA (stand-by), 63 dBA (operation avg.)

Physical dimensions

  • Width (disk/rack): 120 cm / 170 cm 47.2 in / 67 in
  • Depth (disk/rack): 73 cm / 95 cm 28.7 in / 37.4 in
  • Height: 80 cm / 31.4 in (closed top cover) 109 cm / 43 in (opened top cover)

Weight

  • Disk: 180 kg / 397 lbs
  • Rack: 250 kg / 551 lbs

ROCHE Cobas e 411 Chemistry Analyzer

RANDOX Daytona Chemistry Analyzer

Product Features

  • Capable of running 180 photometric tests and 270 ISE tests per hour
  • Barcode identification of both samples and reagents
  • 40 cooled reagent positions
  • 40 positions for multiple primary sample tubes or sample cups
  • Halogen tungsten lamp with eight filters providing wavelength coverage at 340, 415, 510, 546, 570, 600, 660 and 700nm
  • Capable of running colorimetric and UV methods with endpoint, kinetic, monochromatic, bichromatic, turbidimetric, sample and reagent blanking options
  • The STAT sample interrupt function allows emergency samples to be introduced at any time.
  • User friendly Windows ® based software
  • Extensive user defined onboard QC package – sophisticated QC software can be connected to your laboratory information management system (LIS/LIMS). As well as generating Levey Jennings charts it allows the operator to apply user defined rules to identify any trends or bias quickly and easily.
  • Low water consumption of 7.5 litres per hour reduces laboratory running costs and environmental impact
  • Reusable Pyrex cuvettes can be used for up to 5 years dramatically reducing the cost of laboratory consumables
  • Lowest service requirements in its class

RANDOX Daytona Chemistry Analyzer

OLYMPUS AU640e Chemistry Analyzer

  • Analytical system: Fully automated, for routine, STAT, urine and homogeneous immunoassays
  • Analytical methods: Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE
  • Simultaneously processed analytes: 48 photometric tests, 51 with ISE
  • Throughput: 800 photometric tests/hour; maximum of 1,200 with ISE
  • Sample feeder: Racks with 10 samples each (bar codes on primary tubes and on racks); capacity of 150 samples; continuous loading
  • Sample tubes: In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm
  • STAT samples: Up to 22 positions for STAT samples, bar coded primary tubes
  • Sample volume: 2 – 50 µl in 1 µl steps (1 – 50 µl for repeats)
  • Reagent supply: 48 positions for R1 and R2; refrigerated (4 °C – 12 °C)
  • Reagent volume: 1. reagent: 25 – 300 µl; 2. reagent: 25 – 300 µl; (in 1 µl steps)
  • Total reaction volume: 150 – 550 µl
  • Reaction cuvette: Quartz cuvettes
  • Reaction time: Up to 8 minutes, 40 seconds
  • Reaction temperature: 37 °C
  • Mixing method: With rotating paddles after dispensing sample and reagent
  • Photometry system: Direct assay through the reaction cuvette (0 – 2.5 OD) mono, bichromatic measurements possible
  • Wavelength: 13 different wavelengths between 340 – 800 nm
  • Cuvette cleaning: Comprehensive cleaning with detergents
  • Calibration: Auto calibration, cooled calibrator positions
  • Quality control: Auto QC, cooled QC positions
  • Test requisition: Individual and profile test requisition via on line, mouse, functions keys or touch screen
  • Safety: Clot detection and crash prevention for sample and reagent dispenser
  • On-line: Full uni- and bidirectional communication possible
  • Software: Windows-NT

OLYMPUS AU640e Chemistry Analyzer

OLYMPUS AU640 Chemistry Analyzer

Manufacturer: Olympus Diagnostics
Type: Chemistry Analyzer
Parameters: 99 analytes
Throughput: 800 samples/hour, 1200 w/ise
Method: Spectrophotometric
Open system: Open

OLYMPUS AU640 Chemistry Analyzer