Need Help? (720) 278-4104 8am - 6pm MST.

Selling pre-owned medical equipment

Shop Now!

SIEMENS Advia 2400 Chemistry Analyzer

Price: $19,995.00

Loading Updating cart...

Product Overview:

The ADVIA® 2400 Clinical Chemistry System meets today’s high turnaround-time (TAT) goals with a throughput up to 2400 tests/hour. Besides assays for general and specialty chemistries, its menu includes assays for specific protein measurement, drugs-of-abuse testing (DAT) and therapeutic drug monitoring (TDM). Interesting new assays such as Cystatin C, HbA1c with automated sample pretreatment and CardioPhase® hsCRP can now be included into your routine testing.

The ADVIA 2400 Chemistry System pushes productivity levels while maintaining the reliability and stability that keep laboratories up and running. A rapid 2-second probe cycle time maximizes tube speed and test throughput, and combines with the system’s efficient automation-readiness to provide the turnaround time needed for high-volume laboratories

Product Specifications:

General Specifications

  • Power Requirements: 100/115/200/220/230/240 V +/– 10%, 30 A, 50/60 Hz, 3 KVA
  • Water Requirements: Deionized water
  • Maximum Water Consumption: 40 liters per hour
  • Drain requirements: Minimum of 10.6 gallons (40) liters per hour.
  • Dimensions:
    ADVIA 2400: 52.8 (h) x 67.4 (w) x 34.1 (d) in, 134 (h) x 171.1 (w) x 86.7 (d) cm
    Universal Rack Handler: 37 (h) x 29 (w) x 41 (d) in, 86.4 (h) x 73.7 (w) x 104.1 (d) cm
  • Weight:
    ADVIA 2400: 1,389 lbs. (630 kg)
    ADVIA Rack Handler: 178 lbs.(81 kg)
  • Compliance: cUL, CSA, CE
  • Noise Specifications: Open cover less than 70 db, closed cover less than 45 db
  • Average Heat Output: 5,374 BTU/hour
  • Operating Temperature Range: 18° - 30°C/64° - 86°F
  • Ambient Humidity: 40% - 70%
  • Type of System: Random, continuous access, batch, discrete processing
  • Throughput Rate: Up to 2400 tests/hour: 1800 tests/hour colorimetric, 600 tests/hour ISE
  • Assays Capacity Onboard: 49 including 3 ISE

Sample Handling

  • Sample Tubes: 5 mL, 7 mL, 10 mL, 2 mL sample cups
  • Sample Tray: 84 samples, positive sample identification
  • Bar Codes: Interleaved 2 of 5, code 39, code 128, Codabar (NW7)
  • STAT Sample Loading: 84, not dedicated
  • Sample Rack Handler Option: Universal 5-position rack, 425 total Onboard capacity, continous feed capability
  • Auto-repeat: Automatic repeat testing from the retained pre-diluted sample
  • Auto-dilution: Automatic dilution from retained pre-diluted sample
  • Auto-reflex Testing: Automatic ability to perform 3 additional tests based on results of first test
  • Primary Probe: Liquid Level Sensing, Crash Protection, Clot/Clog Detection, Short Sample Detection
  • Sample Integrity Check: Qualitative check for hemolysis, lipemia and icterus

Microvolume Technology

  • Automatic Sample Predilution: Samples diluted 1:5 (30 μL sample + 120 μL saline generates up to 15 test results), retained for auto-repeat until results are available
  • Predilution Tray: 120 dilution cuvettes
  • Original Sample Volume: 2 to 30 µL; system uses an average of 2-3 µL per test
  • Average Reagent Volume: 80-120 µL per test
  • Storage Capacity Onboard: 20,000 tests average; Usage of concentrated reagents increases maximum capacity

Reaction Area

  • Reaction Tray: 340 reusable plastic cuvettes
  • Cuvette Optical Path Length: 6 mm
  • Reaction Bath: Inert fluorocarbon oil circulation system, 37°C
  • Photometer: 14 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, and 884 nm)
  • Light Source: 12V, 50W halogen lamp, cooled by forced water circulation
  • Assay Methods: Endpoint, rate reaction, 2-point rate, multi-point homogeneous immunoassay
  • Reaction Times: 3, 4, 5, 10, 15 and 21 minutes
  • Automatic Correction: Serum blank, cell blank, measurement point change, sample volume change in reassay
  • Point Forwarding: Automatically extends linerarity over assay range samples

Reagent Handling

  • Reagent Tray: 2 trays, 50 positions each, refrigerated
  • Reagent Capacity Onboard: 46 colorimetric methods
  • Dispensing System: 2 probes with Liquid Level Sensing and Liquid Surface Verification
  • Reagent Wedges: 20, 40 and 70 ml bar-code-labeled wedges
  • Onboard Stability: Up to 60 days
  • Reagent Inventory Management: Tracks tests remaining, lot number, onboard stability and expiration date
  • Reagent Dilutions: Capability to dilute concentrated reagents onboard

Open System Capability

  • Channels: 200 channels, includes user-defined applications
  • 3rd Party Applications: Varies by country, can be configured on system

ISE

  • ISE: Indirect simultaneous measurement of Na+, K+, Cl-
  • Sample Volume: 22µL for all three tests
  • Priming: Automatic priming cycle
  • Electrode Life: 30,000 samples or 3 months
  • Throughput Rate: 600 tests/hour; 200 tubes/hour

Calibration/QC

  • Calibration Interval: Up to 60 days, tracked by software
  • Auto-Calibration/Auto-QC: User-defined time interval or with new reagent wedge
  • View Calibration/QC Data: Graphical display of calibration curve and QC, Siemens Remote Service QC monitoring
  • Calibration/Control Tray: 61 refrigerated positions for calibrators, controls and diluents

Data Management

  • Computer: Windows® XP, flat panel display
  • System Documentation: Operator manual and assays sheets on-line
  • Host Interface: RS 232C bidirectional
  • Data Storage: 70,000 patient samples
  • Onboard Maintenance Logs: Schedule and monitor routine maintenance activities via software
  • Host Query: ASCII; system requests work order or batch of work orders from host

SIEMENS Advia 2400 Chemistry Analyzer